Density Meter
 
Service : For all types of liquids and slurrys
Working principle : Online density measurement by Gama rays
Accuracy : 0.5% FSD
Mounting : Online Non contact type
Detector Housing : Rugged steel enclosure  IP 67 connects to control unit with instrumentation cable
Scientillation Detector : Sodium Iodide with integral photo multiplier
Power Supply : 110 V AC or 230 V AC
No loss of Power with power failure
Communication Port : RS 422 Link
Output of the transmitter : 4 to 20 mA
Temperature Drift : +0.00003 SG units per degree C
Repeatability : 0.0001 SG units typical and 0.0002 SG units maximum
Max. Fluid Temp. : up to 50 degree C
Vibration : 2 G at 100 Hz
Humidity : 5 to 95 % RH, non condensing
Application : For online density measurement of fluid passing through the pipe line. Mainly used in pharmaceutical and food industries, Steel Plants etc.
 
 
 
   
   

Home Profile Contact us Careers System Automation Tailor Made Instrumentation Density Conductivity & PPM Flow & Velocity Level Temperature Differential Pressure Pressure & Vacuum